Home›Journal›CAT5e, CAT6, CAT6A: what an HDBaseT reach figure assumes
ENGINEERING · 2 October 2026 · 5 min read

CAT5e, CAT6, CAT6A: what an HDBaseT reach figure assumes.

The HDBaseT Alliance's own reach figures change with the cable. What a 70 m or 100 m figure assumes — category, solid core, shielding, terminations, patch points, bundling — and how to write it into a specification.

JOURNAL / 018
WHAT THE FIGURE ASSUMES ABOUT THE CABLEHDBaseT 1.01080P100 M · CAT5e AND UPHDBaseT 1.04K70 M · CAT5e AND UP100 M · SELECT CAT6AHDBaseT 2.04K60 4:2:0 · 4K30 4:4:490 M · CAT5e100 M · CAT6HDBaseT 3.04K60 4:4:4 · UNCOMPRESSED100 M · CAT6A U/FTPRECOMMENDED0 M507090100 MREACH OVER ONE LINKHIGHER CLASS NAMEDGENERATION FIGURES AS THE HDBaseT ALLIANCE STATES THEM — A PRODUCT'S DATASHEET STATES ITS OWN REACH, FORMAT AND CABLE CLASS
The HDBaseT Alliance's own figures, by generation and cable class: the better the line, the better the cable the number assumes.

An HDBaseT reach figure assumes a cable as much as an extender. The HDBaseT Alliance's own figures move with category and generation: 4K to 70 m over CAT5e under HDBaseT 1.0, and uncompressed 4K60 4:4:4 to 100 m under 3.0, with CAT6A U/FTP recommended. A product's figure carries the same kind of condition — a stated cable class, run solid-core, correctly terminated and lightly patched — and holds when the installed link matches it.

This is the cable side of The distance figure — and its footnote.

What does each HDBaseT generation assume about the cable?

The Alliance states each generation's figures against a cable class. HDBaseT 1.0 requires CAT5e as the minimum compatible cable and recommends CAT6; it quotes 1080p to 100 m over CAT5e and up, and 4K to 70 m — 100 m for select CAT6A. HDBaseT 2.0 (2013) extended 4K30 4:4:4 and 4K60 4:2:0 to 100 m over CAT6, or 90 m over CAT5e. HDBaseT 3.0 (2019) doubled the uncompressed data rate to a native 16 Gbps, carrying uncompressed 4K60 4:4:4 to 100 m, with U/FTP CAT6A recommended to keep near-end and far-end crosstalk to a minimum.

The more a generation asks of the line, the better the cable its figures assume.

How does an 18 Gbps HDMI signal fit a smaller link?

HDMI 2.0 raised the interface to 18 Gbps for 4K60 — a payload of about 14.25 Gbps after TMDS line coding. The Alliance puts the uncompressed threshold of HDBaseT 1.0 and 2.0 at the equivalent of 8.91 Gbps of HDMI. Carrying 4K60 4:4:4 over a second-generation link therefore needs up to 2:1 effective reduction.

The Alliance ratified a light compression method — VESA Display Stream Compression, with latency in the tens of microseconds — as an interim way to carry the equivalent of an 18 Gbps signal over HDBaseT 2.0, and states that no other compression method is approved. It also cautions that some manufacturers instead subsample chroma and reduce bit depth to fit, and that colour discarded that way cannot be recovered. HDBaseT 3.0 carries the format natively by doubling the symbol rate on the pairs — which is why it asks more of the cable. Format, link and cable are one decision; a datasheet that states the format, the distance and the cable class together has already made it.

What does “CAT5e is fine” really mean?

Categories are bandwidth ratings: CAT5e is specified to 100 MHz, CAT6 to 250 MHz and CAT6A to 500 MHz — Classes D, E and EA in ISO/IEC 11801. “CAT5e is fine” is true where a product is rated over CAT5e: at that product's stated format and distance, on compliant solid-core cable, correctly terminated. It is not a promise that any CAT5e run carries any format to 100 m.

“CAT6A recommended” is about margin: the highest rated bandwidth of the three, tested for alien crosstalk, and the category the third generation recommends. As the Alliance puts it, cable installed today should suit the best application it may foreseeably carry — specify for the life of the cable, not the first pair of extenders it serves.

What does the cable itself have to be?

Solid-core. TIA and ISO/IEC standards both require solid conductors for the horizontal permanent link. Stranded cable shows 20 per cent (24 AWG) to 50 per cent (26 AWG) more insertion loss, which is why it is confined to patch cords.

Correctly terminated. For CAT5e, 6 and 6A, pair twists are maintained to within 13 mm of the termination; a poorly twisted termination is a source of excessive crosstalk.

Screened where specified, and bonded. A screen does its work when it is continuous and grounded: a properly bonded system carries induced noise to ground along the screen, away from the pairs. On screened cable, fit shielded jacks and plugs and bond the screen as the system requires.

How much do patch panels and couplers cost?

The Alliance describes HDBaseT's worst-case channel as 90 m of infrastructure cable, CAT5e or better, plus two 5 m patch cables. Patch cables and connectors add reflections and attenuation that erode margin; its guidelines prefer a single run, “purely to be on the safe side”, though both approaches work with compliant cable installed to them. Every connection point adds insertion loss, and Fluke Networks' guidance calls female inline couplers a high source of crosstalk, not to be used in a data installation. A run that is too short is replaced, not extended.

Why do bundled runs interfere with each other?

Alien crosstalk is the coupling of one cable's signal onto another. In 10 Gb Ethernet, transceiver signal processing cancels crosstalk from inside a cable but not noise arriving from a neighbour. CAT6A is tested for it, six disturbing cables around one victim, and a screen improves it significantly. A tight bundle of HDBaseT runs leaving a matrix rack is the same arrangement. Dress bundles neatly, not tightly: over-tightened ties press cables together.

How to write cable into the specification

  • Reach with its conditions — distance, format and cable class as the datasheet states them, with the installed length inside that figure.
  • Cable — category (CAT6A for new work), screen type (U/FTP where the generation or product recommends it), solid-core for the permanent link, cords of the same category.
  • Terminations — shielded jacks and plugs on screened cable, twists kept within 13 mm, screens bonded; no inline couplers; near-limit runs terminated directly.
  • Proof — each permanent link certified to its category with the results handed over, then the HDBaseT link commissioned at the room's real format.

Our cabling guide carries the same discipline. The figure on the datasheet is honest; the cable is how it stays that way.

Questions, answered briefly

Is CAT5e enough for HDBaseT?
CAT5e is the minimum cable HDBaseT was designed for, and the HDBaseT Alliance quotes 1080p to 100 m over CAT5e and up. At 4K the Alliance's figures depend on the generation and the cable class, so rely on the reach a product's datasheet states for your format and the cable you will install. For new cabling, CAT6A gives the most margin.

Does HDBaseT carry 4K60 4:4:4 uncompressed?
HDBaseT 3.0 does: the Alliance quotes a native 16 Gbps link carrying uncompressed 4K60 4:4:4 up to 100 m, and recommends CAT6A U/FTP for it. For HDBaseT 2.0, the Alliance ratified VESA Display Stream Compression as an interim way to carry the equivalent of an 18 Gbps HDMI signal.

Do patch panels reduce HDBaseT distance?
Every connection point adds loss and erodes margin. The HDBaseT Alliance describes its worst-case channel as 90 m of infrastructure cable plus two 5 m patch cables, and its guidelines prefer a single run to be on the safe side. Avoid inline couplers and terminate near-limit runs directly.

Should HDBaseT cable be shielded?
The HDBaseT Alliance recommends U/FTP CAT6A for HDBaseT 3.0 to minimise crosstalk. Where cable is screened, the screen works only when it is continuous and properly bonded, so use shielded jacks and plugs and bond the screen as the cabling system requires.