Ten items per level of the TCE (TELECIS Certified Engineer) examinations, with the answers — and the reasoning. Published so a candidate knows the standard before enrolling, and so anyone specifying against the credential can see exactly what it asks.
These items are specimens of the TCE (TELECIS Certified Engineer) examinations: written to the live blueprints, reviewed and trialled like live items, and permanently excluded from live papers. They demonstrate format, depth, and — in the rationales — the way the examination thinks: requirement first, mechanism second, fashion never.
Work them closed book. A miss is not a verdict; the rationale names the domain, and the learning paths sequence the reading that repairs it.
Ten items in the format and at the standard of the live paper — with the answer, and the reasoning. Domains reference the published TCE-Core blueprint.
A — 4K60 · 4:2:0 · 8-bit
B — 4K30 · 4:4:4 · 8-bit
C — 4K60 · 4:4:4 · 8-bit
D — 4K60 · 4:4:4 · 10-bit
A — HDCP falling back to 1.4
B — chroma subsampling to 4:2:0 somewhere in the path
C — EDID capping the format at 1080p
D — cable attenuation at the top TMDS rate
A — pass through the projector's EDID — it is the safest common format
B — present a fixed internal 4K EDID at each input, and scale at the projector's output
C — clone the EDID of the largest display to all inputs and outputs
D — disable EDID and force the sources manually
A — replace the HDMI cable with an active optical cable
B — train users to reboot the PC after the matrix
C — persistent EDID emulation at the matrix input, so the source always sees a display
D — a longer HDMI handshake timeout at the display
A — passive HDMI cable of premium construction
B — HDBaseT over shielded CAT6A, terminated to standard
C — an AV-over-IP encoder/decoder pair on the corporate LAN
D — DisplayPort with an MST hub at the rack
A — the highest possible image quality
B — zero switching latency
C — endpoint count that will grow across floors and buildings
D — immunity to network outages
A — both displays show the content
B — neither display shows the content
C — the 2.3 display shows it; the 1.4 display shows an HDCP error or black
D — both show it at reduced resolution
A — cable category on the last hop
B — repeater depth and device count against the HDCP topology limits
C — EDID strategy at the source
D — mains earthing at the far rack
A — raise the transmitter's output drive
B — re-terminate as one continuous, directly-terminated run
C — add a mid-span CAT coupler of higher category
D — reduce the format to 1080p and close the ticket
A — connect all sources and displays, then test the room as a whole
B — bring up the matrix alone and verify management access with no sources connected
C — load the control processor's program
D — set EDID on every input from the design document
Ten items at the standard of the written component. The practical is assessed in the lab, against the published rubric — no specimen can substitute for it. Domains reference the published TCE-Advanced blueprint.
A — a standard switching matrix with fast EDID handling
B — a seamless matrix with per-output frame buffering and scaling
C — an AV-over-IP system with IGMP fast-leave
D — a mechanical HDMI patch field
A — cap the whole estate at 1080p for uniformity
B — per-output scaling on the three legacy outputs, native 4K elsewhere
C — external down-scalers at each legacy display
D — replace the three displays before commissioning
A — distribution to 200 endpoints at lowest cost
B — pixel-accurate imagery with imperceptible latency for critical review
C — transport across a WAN to a second site
D — wireless presentation from laptops
A — 1 Gbps — multicast is shared, one copy serves all
B — 2 × 1 Gbps in a LACP bundle
C — 10 Gbps
D — the uplink is irrelevant; traffic stays local to the switch
A — duplicate IP addresses on the encoders
B — IGMP snooping enabled with no querier — multicast flooding as broadcast
C — spanning tree blocking the uplink
D — jumbo frames enabled end to end
A — default VLAN with QoS trust enabled
B — a dedicated AV VLAN with IGMP snooping and one querier, and verified non-blocking capacity for the stream load
C — a separate physical network — nothing else is acceptable
D — port mirroring so AV traffic can be monitored
A — 0.15 ms — always use the minimum
B — 0.25 ms
C — 0.5 ms
D — 5 ms — always use the maximum
A — fail after the lease interval expires
B — continue — subscriptions persist in the devices themselves
C — continue only if a backup controller is elected
D — fall back to analogue
A — update everything simultaneously overnight to minimise version skew
B — pilot one non-critical unit, verify against a checklist, then stage the rollout with a recorded rollback path
C — update only the devices currently exhibiting faults
D — defer all updates until a fault forces the issue
A — the decoder's stream subscription in the management software
B — HDCP negotiation at the display
C — physical link — port state and link lights at the decoder and its switch port
D — the EDID presented to the source
Ten items drawn across the four endorsements — Medical, Broadcast, Command & Control, Hospitality. The live assessment adds a review of submitted installation history; these items illustrate the written standard only.
A — compressed streams cannot carry HDCP
B — codec artefacts on smooth grayscale gradients can be indistinguishable from — or mask — clinical detail
C — compression adds unacceptable cost
D — networks are prohibited in clinical spaces
A — inside the sterile field, closest to the surgeon
B — in the technical zone outside the theatre, with control surfaces at the nurse station and nothing serviceable inside the sterile field
C — in the ceiling void above the table
D — in a rack in the corridor, shared with the adjacent theatre
A — under two frames — low tens of milliseconds
B — a quarter of a second
C — half a second, if image quality is higher
D — latency is irrelevant on a local link
A — their colourimetry matches
B — switches and mixes between sources are clean, with no timing jump at the cut point
C — cable runs can be longer
D — embedded audio stays in sync
A — at the source, so the backbone is HDMI throughout
B — at the display end — SDI to the wall, converted per monitor
C — anywhere — the formats are electrically equivalent
D — nowhere: SDI monitors are mandatory in a gallery
A — both processors from the same production batch
B — source inputs and wall regions distributed so no single failure — processor, PSU, or feed — darkens the whole wall
C — a spare remote control in the operations room
D — matched cable lengths to both processors
A — best-effort latency on the corporate LAN
B — sub-frame video latency and USB switched deterministically with the video, on a qualified network
C — video-only switching, with keyboards attached per computer
D — VNC software on the operators' PCs
A — picture quality exceeds every alternative
B — central management — monitoring, sources, and firmware for the whole estate from one seat, and growth by adding switch ports
C — it eliminates displays' own firmware
D — guests expect visible technology
A — uniformly — every path protected equally
B — by revenue and reputation criticality — dual-pathed sports bar and ballroom, single-pathed corridor signage with spares strategy
C — only to the longest cable runs
D — nowhere — hospitality tolerates failure
A — they are marketing collateral for the integrator
B — they are the auditable evidence — what was installed, configured, verified, and signed, and the baseline every later change is controlled against
C — they are required only when a fault occurs
D — they replace operator training
If the specimens read like a fair day's work, you are ready to prepare properly. Core is complimentary.